Drum screen treatment units
Complete rotary screening assemblies for separating suspended solids from water or process effluent. The screen, feed arrangement, housing, drive, cleaning system and discharge routes are selected together for the actual installation.

Operating principle and configuration
Feed reaches a rotating screening surface. Liquid crosses the openings and retained solids are removed through a separate route. Internally fed units admit flow inside the drum; externally fed units distribute it onto the outer surface. The screen orientation and solids-removal arrangement follow the selected configuration.
A complete unit includes more than the slotted drum element. Feed distribution, available hydraulic head, collection of filtrate, drive, cleaning access and solids handling affect operation. Screening removes the fraction retained by the surface; final effluent quality also depends on the other treatment stages.
Main technical specifications for selection
| Feed and design duty | Water or effluent composition, normal and peak flow, solids loading, particle sizes, fibres, grease and sticky material. |
|---|---|
| Separation target | Solids to retain, permitted carryover and downstream equipment to protect; confirm the required opening against the actual feed. |
| Screen and flow configuration | Internal or external feed, active surface, slot orientation, usable area and any upstream coarse screening. |
| Hydraulic installation | Inlet and outlet levels, available head, channels or pipe connections, collection and overflow arrangements. |
| Cleaning and utilities | Spray coverage and wash-water conditions, mechanical cleaning where fitted, electrical supply and permitted cleaning discharge. |
| Solids handling | Discharge position and elevation, chute or container interface, drainage and removal frequency. |
| Materials and access | Fluid chemistry, corrosion and wear, compatible screen and housing materials, lifting access and service space. |
| Package and control scope | Drum, housing, frame, drive, wash system and controls; define start/stop logic, required alarms and supplied documentation. |
Technical arrangement

Equipment photographs
Installation, inspection and cleaning
- Check installed levels, flow direction and feed distribution before commissioning; uneven loading can leave part of the screen unused.
- Verify drive rotation, guards, clearances and cleaning operation using the equipment commissioning procedure.
- Inspect the screen for plugging or wear and check spray nozzles, seals, supports and the solids discharge path during planned service.
- Keep the filtrate and solids routes clear. Record changes in feed, retained solids and cleaning frequency when investigating reduced performance.
Related filter equipment
Request a technical review
Send normal and peak flow, effluent and solids data, required separation, inlet/outlet levels, available installation space and utilities. Specify a complete treatment unit, an existing-machine review or a replacement drum element.