Wedge wire resin traps
A protective screening element or assembly in the outlet line of a media treatment unit. Its duty is to intercept the specified escaped resin or media particles before they reach downstream equipment.

Operating principle and configuration
Liquid passes through a slotted element fitted inside a housing or line assembly. The specified particles are retained on the working surface. This outlet protection has a different duty from the internal laterals or nozzles that normally hold the bed in the upstream vessel.
Specify whether the order is for a replacement screen element or a complete resin-trap assembly. An element has its own mounting, sealing and differential-pressure requirements; the housing, line connections and design pressure require separate definition.
Main technical specifications for selection
| Media to be retained | Resin or other media type, size distribution and expected broken beads or fines; state the retention objective. |
|---|---|
| Fluid and flow | Normal and maximum flow, viscosity, temperature, fluid chemistry and cleaning chemicals. |
| Slot selection | Nominal opening and tolerance matched to the target particles. A slot value alone does not define the behaviour of all broken or irregular particles. |
| Element geometry | Overall and active length, diameter, flow direction, wire and support profiles and any reinforcement. |
| Mounting and sealing | Element seat, end connections, seal material, positive retention and removal clearance to prevent bypass. |
| Pressure conditions | Housing operating and design conditions, plus clean and fouled-element differential pressure and any permitted reverse cleaning. |
| Monitoring | Locations for upstream and downstream pressure measurement and the agreed alarm, isolation or shutdown response. |
| Scope and inspection | Replacement element or full assembly; connection standard, access, quantity, material identification and agreed dimensional and weld checks. |
Technical arrangement

Installation, inspection and cleaning
- Confirm the flow direction, element seating and seals before service, then record the clean-element pressure difference at a known flow.
- Investigate a rise in differential pressure or collected media. Cleaning the trap does not resolve the reason media escaped from the upstream unit.
- Before opening the housing, isolate and depressurize the equipment using the site’s approved procedure.
- Inspect for damaged slots, welds, corrosion and seal leakage. Clean by the agreed method and compare the pressure difference at a similar flow after reassembly.
Related filter equipment
Request a technical review
State whether an element or complete assembly is required. Include media grading, flow, fluid and temperature, slot requirement, housing and element drawings, connections, pressure conditions and monitoring requirements.