Wedge wire filtration in power generation plants
Intake screening, cooling-water straining and media retention serve different points in a power plant’s water system. Specify the water source, downstream equipment and allowable flow restriction for each duty.

Process duties and selection approach
An intake screen intercepts specified solids before water enters a suction line. A line strainer or self-cleaning filter serves another location in the circuit and requires its own pressure, connection and cleaning data. Slot size is considered with peak flow, active area and the available pressure-drop allowance.
Water-treatment internals perform a separate function: header and lateral assemblies collect or distribute flow while retaining a bed, and a downstream resin trap catches escaped media. Match these components to the treatment vessel, resin grading and service or backwash sequence.
Technical information for the application
| Water source and chemistry | Identify river, reservoir, seawater or process circuit; include temperature, salinity, suspended matter and treatment chemicals. |
|---|---|
| Flow and pump conditions | Provide normal and maximum flow, pump and suction details, and the permitted pressure drop for clean and fouled conditions. |
| Solids to intercept | Describe particle sizes, floating debris, fibres and seasonal changes in the source. |
| Intake installation | Give water-level range, installation depth, surrounding clearance, outlet connection and support arrangement. |
| Openings and material | Select slot width and active area together; match the alloy to actual water chemistry and cleaning conditions. |
| Media-retaining internals | For treatment vessels give media grading and bed depth, branch layout, bed supports and flow direction in service and backwash. |
| Cleaning and access | Define manual removal, wash or backwash provisions, available utilities and access for isolation and inspection. |
| Project requirements | State the supply boundary, inspection documents and any intake environmental requirements to be assessed for the complete arrangement. |
Technical arrangement

Equipment photographs
Installation, inspection and cleaning
- Check outlet connections, supports and the cleaning arrangement before commissioning.
- Track pressure drop or suction performance and inspect for debris accumulation, especially during seasonal changes.
- Inspect joints and seals in media-retaining assemblies as well as the slots; gaps can allow media bypass.
- Confirm the permitted reverse flow and loading before changing the cleaning or backwash sequence.
Relevant filter equipment
Request a technical review
Send the water source and analysis, normal and peak flow, pump or vessel data, solids or resin grading, allowable pressure drop, layout drawing and proposed cleaning method.